Application:
Measuring the volume of cold potable water passing through the pipeline
Quality:
•Its digital wheels are sealed in the liquid-capsule and kept legible for reading.
•Available with non-return valve, inlet strainer and pulse output on request.
•High quality material applied to guarantee its function efficient and durable.
•The accuracy excels Class C stated in ISO 4064
Working condition:
temperature:
≤40℃for cold water
Pressure: ≤1Mpa
Maximum Permissible Error:
Qmin→Qt(ex Qt)=±5%;
Qt→Qs(both included)=±2% or ±3%(hot water)
Qmin=Min Flow, Qt=Transition Flow, Qs= Max Flow.
| Tpye | Meter Size | class | Maxflow | Nominal Flow |
Transition Flow |
Min Flow | Min Reading |
Max Reading |
|---|---|---|---|---|---|---|---|---|
| mm | m3/h | L/h | m3 | |||||
| LXS-15F | 15 | B | 3 | 1.5 | 120 | 30 | 0.0001 | 99999 |
| C | 22 | 15 | ||||||
| LXS-20F | 20 | B | 5 | 2.5 | 200 | 50 | 0.0001 | 99999 |
| C | 37.5 | 25 | ||||||
| Tpye | Meter Size | Length | Wide | Heigh | Connecting Thread | weight |
|---|---|---|---|---|---|---|
| mm | D | kg | ||||
| LXS-15F | 15 | 165 | 95 | 105 | G 3/4B | 1.2 |
| LXS-20F | 20 | 190 | 95 | 105 | G 1B | 1.7 |